Share:

YANCEYVILLE STREET over NORTH BUFFALO CREEK

Map

Coordinates:
+36.10003, -79.77510
36°06'00" N, 79°46'30" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:YANCEYVILLE STREET over NORTH BUFFALO CREEK
Structure number:000000000810434
Location:0.1MI.S.JCT.CORNWALLIS DR
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Urban) [19]
Length of largest span:45.9 ft. [14.0 m]
Total length:95.1 ft. [29.0 m]
Roadway width between curbs:44.0 ft. [13.4 m]
Deck width edge-to-edge:56.1 ft. [17.1 m]
Skew angle:15°
Owner:City or Municipal Highway Agency [04]
Year built:1958
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: February 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:13,000 [as of 2013]
Truck traffic:6% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:53.7
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
February 2018FairSatisfactoryFairSatisfactory1300053.7
February 2016FairSatisfactoryFairSatisfactory1500059.6
January 2014FairSatisfactoryFairSatisfactory1500059.6
January 2012FairSatisfactoryFairSatisfactory1500059.6
January 2010FairSatisfactoryFairSatisfactory790061.1
April 2008FairSatisfactoryFairSatisfactory790054.8
April 2006FairSatisfactoryFairSatisfactory790054.8
May 2004FairSatisfactorySatisfactorySatisfactory790052.6
April 2002FairGoodSatisfactoryGood790068.9
May 2000FairGoodSatisfactoryGood790068.9
May 1998FairGoodSatisfactorySatisfactory790068.9
June 1990PoorGoodPoorSatisfactory790043.3