Share:

US25 over SR1103

Map

Coordinates:
+35.19785, -82.45097
35°11'52" N, 82°27'03" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US25 over SR1103
Structure number:000000000890078
Location:1.4 MI.S.JCT.SR1106
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:79.1 ft. [24.1 m]
Total length:168.0 ft. [51.2 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:42.0 ft. [12.8 m]
Vertical clearance below bridge:18.0 ft. [5.5 m]
Skew angle:38°
Owner:State Highway Agency [01]
Year built:1980
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 9 / H 10 [1]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: July 2009

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:6,500 [as of 2008]
Truck traffic:14% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Better than present minimum criteria [7]
Underclearances appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:70.3 tons [63.9 metric tons]
Inventory rating:41.6 tons [37.8 metric tons]
Sufficiency rating:99.4

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
July 200999.4FairSatisfactoryVery GoodGood-6500
September 199996.4FairSatisfactoryVery GoodGood-6000
September 199199.9FairSatisfactoryVery GoodSatisfactory-2000

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.1,0021,002000
Steel Protective Coatingsq. ft.9,1209,120000
Deck
Reinforced Concrete Decksq. ft.7,0437,0232000
Substructure
Reinforced Concrete Columneach88000
Reinforced Concrete Abutmentlinear ft.140140000
Reinforced Concrete Pile Cap/Footinglinear ft.1515000
Steel Pileeach1818000
Reinforced Concrete Pier Caplinear ft.228228000
Joints
Pourable Jointlinear ft.108108000
Bearings
Movable Bearingeach1817100
Steel Protective Coatingsq. ft.1817100
Fixed Bearingeach1818000
Steel Protective Coatingsq. ft.1818000
Bridge Rail
Other Material Bridge Raillinear ft.3382944400