Share:

NC12 over ISLAND CREEK

Map

Coordinates:
+35.12702, -75.92144
35°07'37" N, 75°55'17" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:NC12 over ISLAND CREEK
Structure number:000000000950010
Old structure number:000000000095010 (from 1992 edition)
Location:3.3 MI. N. JCT. SR 1333
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:45.9 ft. [14.0 m]
Total length:149.9 ft. [45.7 m]
Roadway width between curbs:33.1 ft. [10.1 m]
Deck width edge-to-edge:36.1 ft. [11.0 m]
Skew angle:30°
Owner:State Highway Agency [01]
Year built:2008
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 9 / H 10 [1]
Number of main spans:3
Main spans material:Prestressed concrete [5]
Main spans design:Slab [01]
Deck type:Concrete Precast Panels [2]
Wearing surface:Bituminous [6]

Latest Available Inspection: April 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:1,700 [as of 2015]
Truck traffic:7% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:68.3
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2017FairSatisfactoryFairGood170068.3
April 2015GoodGoodGoodGood190079.7
April 2013GoodGoodGoodGood140083.4
April 2011GoodGoodGoodGood110085.7
April 2009GoodGoodGoodVery Good210078.0
April 2008GoodGoodVery GoodVery Good210078.0
October 2006PoorVery GoodSatisfactoryPoor530039.0
September 2004FairVery GoodSatisfactoryFair530047.0
December 2001FairVery GoodSatisfactoryFair780047.0
May 1999FairVery GoodSatisfactoryFair600047.0
May 1997FairFairSatisfactoryFair70056.6
May 1995FairFairSatisfactoryFair70027.6
May 1993FairFairSatisfactoryFair70027.6
July 1991FairFairSatisfactoryFair70043.8