Share:

NC12 FERRY over PAMLICO SOUND

Map

Coordinates:
+35.11557, -75.98644
35°06'56" N, 75°59'11" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:NC12 FERRY over PAMLICO SOUND
Structure number:000000000950115
Location:S.END OF NC12
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:43.0 ft. [13.1 m]
Total length:108.9 ft. [33.2 m]
Roadway width between curbs:14.1 ft. [4.3 m]
Deck width edge-to-edge:18.0 ft. [5.5 m]
Vertical clearance above deck:13.8 ft. [4.2 m]
Owner:State Highway Agency [01]
Year built:1997
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 9 / H 10 [1]
Main span material:Steel [3]
Main span design:Girder and floorbeam system [03]
Deck type:Steel plate (includes orthotropic) [5]
Wearing surface:Other [9]

Latest Available Inspection: April 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:2,100 [as of 2013]
Truck traffic:7% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:43.2
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2018FairSatisfactorySatisfactoryFair210043.2
April 2016FairSatisfactorySatisfactoryFair210043.2
April 2014FairGoodFairFair210041.8
April 2013FairGoodFairFair210045.1
April 2011PoorGoodPoorFair160034.1
April 2009FairGoodSatisfactorySatisfactory190053.8
April 2007GoodGoodGoodGood210053.8
April 2005GoodVery GoodGoodGood530056.0
August 2003GoodVery GoodGoodGood70062.3
July 2001GoodVery GoodGoodGood70062.3
May 1999GoodVery GoodGoodGood70062.3
July 1991FairFairFairGood70030.0