I85, SR2623,SR2624 over IRWIN CREEK


+35.27464, -80.82640
35°16'29" N, 80°49'35" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.


Name:I85, SR2623,SR2624 over IRWIN CREEK
Structure number:000000001190244
Location:0.5 MI. N. JCT. SR2691
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:9.8 ft. [3.0 m]
Total length:32.2 ft. [9.8 m]
Owner:State Highway Agency [01]
Year built:1957
Year reconstructed:1989
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 9 / H 10 [1]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: July 2016 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:168,000 [as of 2013]
Truck traffic:16% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:35.0 tons [31.8 metric tons]
Inventory rating:27.0 tons [24.5 metric tons]
Sufficiency rating:62.8
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]

Previous Inspections 

DateSuff. RatingConditionCulvert ConditionSD/FOADT
July 201662.8Fair6 out of 10-168000
July 201462.8Fair6 out of 10-164000
July 201250.8Fair5 out of 10-164000
August 201070.0Fair6 out of 10-167000
September 200870.0Fair6 out of 10-151000
September 200670.0Fair6 out of 10-151000
August 200470.0Fair6 out of 10-158000
September 200270.0Fair6 out of 10-145000
September 200070.0Fair6 out of 10-140000
December 199770.0Fair6 out of 10-137700
December 199175.2Fair6 out of 10-85900