Share:

BEATTIES FORD ROAD over NC16 & SCL.RR

Map

Coordinates:
+35.24979, -80.85646
35°14'59" N, 80°51'23" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:BEATTIES FORD ROAD over NC16 & SCL.RR
Structure number:000000001190348
Location:0.5 MI. N. JCT. I77
Purpose:Carries highway and pedestrian walkway over highway and railroad
Route classification:Local (Urban) [19]
Length of largest span:100.1 ft. [30.5 m]
Total length:356.0 ft. [108.5 m]
Roadway width between curbs:51.8 ft. [15.8 m]
Deck width edge-to-edge:64.6 ft. [19.7 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Skew angle:40°
Owner:State Highway Agency [01]
Year built:1972
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 9 / H 10 [1]
Number of main spans:5
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: September 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:16,000 [as of 2012]
Truck traffic:7% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge not over waterway. [N]
Operating rating:71.8 tons [65.3 metric tons]
Inventory rating:42.9 tons [39.0 metric tons]
Sufficiency rating:66.7
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
September 201666.7FairFairFairFair-16000
September 201466.7FairFairFairFair-16000
September 201266.7FairFairFairFair-16500
September 201078.0FairFairGoodSatisfactory-17000
September 200877.6FairFairGoodSatisfactory-20000
December 200679.0FairSatisfactoryVery GoodGood-17500
December 200379.0FairSatisfactoryVery GoodGood-17500
March 200274.7FairSatisfactoryVery GoodGoodFO18150
February 200074.7FairSatisfactoryVery GoodGoodFO18150
October 199174.7FairSatisfactoryVery GoodGoodFO15300

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.2,8082582,488620
Steel Protective Coatingsq. ft.1,0509760074
Deck
Reinforced Concrete Decksq. ft.18,502010,1378,3650
Substructure
Reinforced Concrete Columneach2015410
Reinforced Concrete Abutmentlinear ft.22011001100
Steel Pileeach2020000
Reinforced Concrete Pier Caplinear ft.49438281040
Bearings
Elastomeric Bearingeach3939000
Other Bearingeach57442110
Steel Protective Coatingsq. ft.1281030025
Bridge Rail
Other Material Bridge Raillinear ft.714071400