Share:

SHARON ROAD over LITTLE SUGAR CREEK

Map

Coordinates:
+35.11832, -80.86812
35°07'06" N, 80°52'05" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SHARON ROAD over LITTLE SUGAR CREEK
Structure number:000000001190387
Location:0.9 MI.E.JCT.S.BLVD.
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:58.1 ft. [17.7 m]
Total length:180.1 ft. [54.9 m]
Roadway width between curbs:47.9 ft. [14.6 m]
Deck width edge-to-edge:61.7 ft. [18.8 m]
Skew angle:10°
Owner:City or Municipal Highway Agency [04]
Year built:1970
Year reconstructed:1993
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: April 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:19,000 [as of 2013]
Truck traffic:6% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:77.7
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2016FairSatisfactorySatisfactoryGood1900077.7
April 2014FairFairGoodGood2000076.6
April 2012FairFairGoodGood990078.8
April 2010FairSatisfactoryVery GoodVery Good990079.8
April 2008FairSatisfactoryVery GoodVery Good990079.8
April 2006GoodGoodVery GoodVery Good990079.8
April 2004GoodGoodVery GoodVery Good990079.8
July 2002GoodGoodVery GoodVery Good990079.8
July 2000GoodGoodVery GoodVery Good990079.8
March 1998GoodGoodVery GoodVery Good990079.8
May 1990FairSatisfactorySatisfactorySatisfactory200082.8