Share:

NC33,NC304 over NC33, I/C WATERWAY

Map

Coordinates:
+35.24554, -76.59117
35°14'44" N, 76°35'28" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:NC33,NC304 over NC33, I/C WATERWAY
Structure number:000000001370015
Location:0.1 MI N JCT NC304
Purpose:Carries highway over highway and waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:380.9 ft. [116.1 m]
Total length:2538.2 ft. [773.6 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:33.1 ft. [10.1 m]
Vertical clearance below bridge:65.0 ft. [19.8 m]
Owner:State Highway Agency [01]
Year built:1997
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 9 / H 10 [1]
Number of main spans:3
Main spans material:Prestressed concrete continuous [6]
Main spans design:Segmental box girder [21]
Deck type:Concrete Precast Panels [2]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: August 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:580 [as of 2013]
Truck traffic:7% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Underclearances appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:In place and functioning [2]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:45.9 tons [41.7 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:79.0

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
August 201579.0FairGoodGoodFair-580
September 201385.2GoodGoodGoodGood-780
September 201192.8GoodGoodGoodGood-300
September 200988.8GoodGoodGoodVery Good-670
December 200783.3GoodGoodGoodVery Good-820
November 200583.1GoodGoodGoodVery Good-840
November 200389.0GoodExcellentGoodVery Good-640
October 200190.2GoodExcellentGoodVery Good-510
October 199977.4GoodExcellentGoodVery Good-1300
May 198747.5FairSatisfactorySatisfactorySatisfactoryFO850

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Reinforced Concrete Closed Web/Box Girderlinear ft.1,010604363430
Prestressed Concrete Girder/Beamlinear ft.6,9606,959100
Deck
Reinforced Concrete Decksq. ft.77,04776,46058700
Reinforced Concrete Top Flangesq. ft.33,38230,3093,07210
Substructure
Reinforced Concrete Columneach2118300
Reinforced Concrete Pier Walllinear ft.6464000
Reinforced Concrete Abutmentlinear ft.140140000
Reinforced Concrete Pile Cap/Footinglinear ft.524522200
Prestressed Concrete Pileeach364364000
Prestressed Concrete Pier Caplinear ft.3028200
Reinforced Concrete Pier Caplinear ft.6786542400
Joints
Compression Jointlinear ft.693693000
Assembly with Sealeach6666000
Bearings
Elastomeric Bearingeach168168000
Steel Protective Coatingsq. ft.160160000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.5,0784,85422400