Share:

SR1125 over SOUTH FLAT RIVER

Map

Coordinates:
+36.26299, -78.63300
36°15'47" N, 78°37'59" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR1125 over SOUTH FLAT RIVER
Structure number:000000001450033
Location:0.3 MI.S.JCT.SR1202
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:39.0 ft. [11.9 m]
Total length:160.1 ft. [48.8 m]
Roadway width between curbs:29.2 ft. [8.9 m]
Deck width edge-to-edge:30.2 ft. [9.2 m]
Skew angle:15°
Owner:State Highway Agency [01]
Year built:1970
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 9 / H 10 [1]
Number of main spans:4
Main spans material:Prestressed concrete [5]
Main spans design:Slab [01]
Deck type:Concrete Precast Panels [2]
Wearing surface:Bituminous [6]

Latest Available Inspection: March 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:870 [as of 2012]
Truck traffic:6% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Operating rating:52.9 tons [48.1 metric tons]
Inventory rating:31.9 tons [29.0 metric tons]
Sufficiency rating:78.3
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
March 201778.3FairGoodGoodFair-870
March 201578.3FairGoodGoodFair-870
March 201376.4FairGoodGoodFair-870
March 201175.1FairGoodGoodFair-860
March 200991.4FairSatisfactorySatisfactorySatisfactory-690
October 200789.0FairSatisfactorySatisfactorySatisfactory-690
June 200390.3FairSatisfactorySatisfactorySatisfactory-690
May 200190.2FairSatisfactorySatisfactorySatisfactory-710
January 199990.4FairSatisfactorySatisfactorySatisfactory-500
January 199189.4FairGoodSatisfactoryGood-200

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Prestressed Concrete Closed Web/Box Girderlinear ft.1,7601,756130
Deck
Prestressed Concrete Top Flangesq. ft.4,7964,796000
Substructure
Timber Abutmentlinear ft.8888000
Reinforced Concrete Pile Cap/Footinglinear ft.2051317400
Steel Pileeach3054210
Steel Protective Coatingsq. ft.5,5505,4628377
Reinforced Concrete Pier Caplinear ft.1701420280
Joints
Pourable Jointlinear ft.9600960
Bearings
Other Bearingeach8888000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.32016016000
Coatings
Wearing Surfacessq. ft.4,6684,54401240