Share:

F ST/FAU 5030 over US75

Map

Coordinates:
+41.21972, -95.95332
41°13'11" N, 95°57'12" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:F ST/FAU 5030 over US75
Structure number:S075 08766
Location:KENNEDY EXP/F ST INTRCHG
Purpose:Carries highway overpass over highway
Route classification:Collector (Urban) [17]
Length of largest span:67.9 ft. [20.7 m]
Total length:213.9 ft. [65.2 m]
Roadway width between curbs:69.9 ft. [21.3 m]
Deck width edge-to-edge:83.3 ft. [25.4 m]
Vertical clearance below bridge:14.8 ft. [4.5 m]
Skew angle:10°
Owner:State Highway Agency [01]
Year built:1970
Year reconstructed:1998
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Low slump Concrete [4]

Latest Available Inspection: February 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:7,380 [as of 2010]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge not over waterway. [N]
Operating rating:46.9 tons [42.6 metric tons]
Inventory rating:27.9 tons [25.4 metric tons]
Sufficiency rating:81.7

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
February 201681.7FairSatisfactoryGoodSatisfactoryFO7380
February 201481.7FairSatisfactoryGoodSatisfactoryFO7380
January 201286.8FairSatisfactoryGoodSatisfactoryFO8200
March 201086.8FairSatisfactoryGoodSatisfactoryFO8200
March 200874.7FairFairSatisfactoryFairFO7900
February 200693.3GoodGoodGoodGood-7200
August 200493.0GoodGoodGoodGood-10000
April 200293.1GoodVery GoodGoodGood-9200
August 200093.2GoodVery GoodGoodGood-8300
August 199892.2GoodVery GoodGoodGood-8300
August 199691.4FairFairGoodGoodFO6100
September 199492.3FairSatisfactoryGoodGoodFO8600
August 199292.3FairSatisfactoryGoodGoodFO8600
September 199097.4FairSatisfactoryGoodGood-8600

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.57726830450
Steel Protective Coatingsq. ft.1,5861,415041130
Deck
Reinforced Concrete Decksq. ft.1,6381,60320150
Wearing Surfacessq. ft.1,3761,3320440
Substructure
Reinforced Concrete Columneach1513200
Reinforced Concrete Abutmentlinear ft.67230440
Reinforced Concrete Pier Caplinear ft.6666000
Bearings
Movable Bearingeach36220140
Fixed Bearingeach99000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.128712100