I80 over I76
Map
Coordinates:
+41.02670, -102.1549141°01'36" N, 102°09'18" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | I80 over I76 |
Structure number: | S080 10259L |
Location: | I76/I80 INTRCHG |
Purpose: | Carries highway overpass over highway |
Route classification: | Principal Arterial - Interstate (Rural) [01] |
Length of largest span: | 97.1 ft. [29.6 m] |
Total length: | 337.0 ft. [102.7 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 26.9 ft. [8.2 m] |
Vertical clearance below bridge: | 16.4 ft. [5.0 m] |
Skew angle: | 45° |
Owner: | State Highway Agency [01] |
Year built: | 1969 |
Year reconstructed: | 2004 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 4 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: October 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 7,600 [as of 2017] |
Truck traffic: | 61% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Underclearances appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 91.9 |
Recommended work: | Widening of existing bridge with deck rehabilitation or replacement. [34] |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
October 2017 | Fair | Good | Good | Satisfactory | 7600 | 91.9 |
October 2015 | Fair | Good | Good | Satisfactory | 6713 | 91.9 |
October 2013 | Good | Good | Good | Good | 6713 | 91.9 |
November 2011 | Good | Very Good | Good | Good | 6993 | 77.7 |
December 2009 | Good | Very Good | Good | Good | 6700 | 59.9 |
December 2007 | Good | Excellent | Good | Good | 7050 | 78.0 |
November 2005 | Good | Excellent | Good | Good | 7075 | 78.0 |
March 2004 | Poor | Poor | Good | Good | 7010 | 75.0 |
October 2001 | Poor | Poor | Good | Good | 30 | 65.2 |
May 1999 | Poor | Poor | Good | Good | 30 | 65.2 |
April 1997 | Poor | Poor | Good | Good | 5725 | 53.2 |
May 1995 | Fair | Satisfactory | Good | Good | 2900 | 57.2 |
June 1993 | Fair | Satisfactory | Good | Good | 2745 | 74.8 |
November 1991 | Fair | Satisfactory | Very Good | Good | 2575 | 76.8 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 1,308 | 1,098 | 210 | 0 | 0 |
Steel Protective Coating | sq. ft. | 15,696 | 15,486 | 0 | 0 | 210 |
Deck |
Reinforced Concrete Deck | sq. ft. | 8,953 | 8,283 | 670 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 9 | 0 | 0 | 9 | 0 |
Reinforced Concrete Abutment | linear ft. | 130 | 76 | 14 | 40 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 113 | 86 | 13 | 14 | 0 |
Joints |
Compression Joint | linear ft. | 75 | 75 | 0 | 0 | 0 |
Bearings |
Movable Bearing | each | 16 | 10 | 2 | 4 | 0 |
Fixed Bearing | each | 4 | 4 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 735 | 590 | 145 | 0 | 0 |