Share:

US281 over CROOKED CREEK

Map

Coordinates:
+40.09945, -98.51877
40°05'58" N, 98°31'08" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US281 over CROOKED CREEK
Structure number:S281 00677
Location:1N RED CLOUD
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Rural) [06]
Length of largest span:26.9 ft. [8.2 m]
Total length:102.0 ft. [31.1 m]
Roadway width between curbs:40.4 ft. [12.3 m]
Deck width edge-to-edge:43.3 ft. [13.2 m]
Owner:State Highway Agency [01]
Year built:1938
Year reconstructed:1975
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:5
Main spans material:Concrete continuous [2]
Main spans design:Slab [01]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: July 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:1,490 [as of 2012]
Truck traffic:13% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:38.0 tons [34.5 metric tons]
Inventory rating:22.0 tons [20.0 metric tons]
Sufficiency rating:68.9

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
July 201568.9FairFairFairFair-1490
July 201368.9FairFairFairFair-1490
July 201173.0FairFairFairFair-1345
August 200973.0FairFairFairFair-1415
August 200773.0FairFairFairFair-1225
September 200573.0FairFairFairFair-1290
October 200372.0FairFairFairFair-1340
August 200171.9FairFairFairFair-1580
August 199971.9FairFairFairFair-1465
October 199772.0FairFairFairFair-1290
August 199570.0FairFairFairSatisfactory-1435
August 199371.0FairFairFairSatisfactory-1320
October 199171.1FairFairFairSatisfactory-1075

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Substructure
Timber Abutmentlinear ft.2626000
Timber Pileeach6051810
Reinforced Concrete Pier Caplinear ft.88652120
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.6060000
Deck
Reinforced Concrete Slabsq. ft.3973643300
Wearing Surfacessq. ft.371371000