Share:

STANLEY AVENUE over PASSAIC RIVER

Map

Coordinates:
+40.72610, -74.38965
40°43'34" N, 74°23'23" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:STANLEY AVENUE over PASSAIC RIVER
Structure number:1400516
Location:AT RIVER ROAD JCT
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Collector (Urban) [17]
Length of largest span:42.0 ft. [12.8 m]
Total length:87.9 ft. [26.8 m]
Roadway width between curbs:36.1 ft. [11.0 m]
Deck width edge-to-edge:49.9 ft. [15.2 m]
Owner:County Highway Agency [02]
Year built:1929
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: August 2031

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:2,500 [as of 1990]
Truck traffic:3% of total traffic
Deck condition:Poor [4 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Scour calculation/evaluation has not been made. [6]
Sufficiency rating:80.5
Recommended work:Bridge deck rehabilitation with only incidental widening. [36]
Estimated cost of work:$26,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2031PoorPoorFairFair250080.5
July 2017FairFairSatisfactorySatisfactory307995.6
August 2015FairFairSatisfactorySatisfactory301995.6
August 2013FairFairSatisfactorySatisfactory296095.6
September 2011FairFairSatisfactorySatisfactory290094.7
August 2009FairSatisfactorySatisfactorySatisfactory276195.7
July 2007FairSatisfactorySatisfactorySatisfactory276195.7
July 2005FairGoodSatisfactorySatisfactory265495.8
June 2003FairGoodSatisfactorySatisfactory255095.8
June 2001FairGoodSatisfactorySatisfactory255095.8
June 1999FairGoodSatisfactorySatisfactory255095.8
June 1997FairSatisfactorySatisfactorySatisfactory255095.8
October 1994PoorPoorFairFair255081.8
August 1992PoorPoorFairFair250080.5

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,1441,1222200
Deck
Reinforced Concrete Decksq. ft.4,4004,254103430
Wearing Surfacessq. ft.3,1682,5291235160
Substructure
Reinforced Concrete Pier Walllinear ft.50026240
Reinforced Concrete Abutmentlinear ft.10091450
Joints
Pourable Jointlinear ft.150015000
Bearings
Enclosed/Concealed Bearingeach5252000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.1761016420