BLACKWELLSMILLS RD over MILLSTONE RIVER
Map
Coordinates:
+40.47472, -74.5761740°28'29" N, 74°34'34" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | BLACKWELLSMILLS RD over MILLSTONE RIVER |
Structure number: | 18G0404 |
Location: | AT RIVER RD INTERSECTION |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Local (Urban) [19] |
Length of largest span: | 53.2 ft. [16.2 m] |
Total length: | 108.9 ft. [33.2 m] |
Roadway width between curbs: | 30.2 ft. [9.2 m] |
Deck width edge-to-edge: | 38.1 ft. [11.6 m] |
Skew angle: | 5° |
Owner: | County Highway Agency [02] |
Year built: | 1994 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Number of main spans: | 2 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: October 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 4,280 [as of 2017] |
Truck traffic: | 1% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Very Good [8 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 77.2 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
October 2017 | Fair | Satisfactory | Very Good | Good | 4280 | 77.2 |
October 2015 | Fair | Satisfactory | Very Good | Good | 4990 | 75.7 |
December 2013 | Fair | Satisfactory | Very Good | Good | 4978 | 75.7 |
December 2011 | Fair | Satisfactory | Very Good | Good | 9880 | 73.4 |
December 2009 | Fair | Satisfactory | Very Good | Good | 4682 | 79.3 |
December 2007 | Good | Good | Very Good | Good | 4682 | 79.3 |
December 2005 | Good | Good | Very Good | Good | 4590 | 79.4 |
November 2003 | Good | Very Good | Very Good | Good | 4500 | 79.4 |
December 2001 | Good | Very Good | Very Good | Very Good | 4410 | 80.4 |
December 1999 | Good | Very Good | Very Good | Very Good | 4326 | 80.5 |
December 1997 | Good | Very Good | Very Good | Very Good | 4326 | 80.5 |
September 1997 | Good | Very Good | Very Good | Very Good | 4200 | 80.5 |
June 1995 | Good | Very Good | Excellent | Very Good | 4200 | 81.4 |
June 1994 | Good | Very Good | Excellent | Very Good | 4200 | 81.4 |
April 1991 | Poor | Fair | Poor | Poor | 2880 | 5.3 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 742 | 742 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 742 | 742 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 4,133 | 0 | 4,133 | 0 | 0 |
Substructure |
Reinforced Concrete Pier Wall | linear ft. | 45 | 30 | 15 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 90 | 82 | 8 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 21 | 21 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 218 | 0 | 218 | 0 | 0 |
Steel Protective Coating | sq. ft. | 654 | 0 | 654 | 0 | 0 |