Share:

NJTPK SNI&O-W SNOE over WILSON AVENUE

Map

Coordinates:
+40.71500, -74.13833
40°42'54" N, 74°08'18" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:NJTPK SNI&O-W SNOE over WILSON AVENUE
Structure number:M10579O
Location:.95 MI N INTERCHANGE 14
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Tolls:Yes, on toll road [2]
Length of largest span:82.0 ft. [25.0 m]
Total length:168.0 ft. [51.2 m]
Roadway width between curbs:146.0 ft. [44.5 m]
Deck width edge-to-edge:159.1 ft. [48.5 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Skew angle:27°
Owner:State Toll Authority [31]
Year built:1970
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: March 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:63,877 [as of 2017]
Truck traffic:7% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:80.1

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
March 2017FairSatisfactorySatisfactoryFair6387780.1
March 2015FairSatisfactorySatisfactoryFair6387780.1
March 2013FairSatisfactoryGoodFair6261880.3
March 2011FairSatisfactoryGoodFair6237080.3
March 2009FairSatisfactoryGoodSatisfactory6114792.3
March 2007FairGoodGoodSatisfactory5876292.5
March 2005GoodGoodGoodGood8884589.7
April 2003GoodGoodGoodGood8884589.7
March 2003GoodGoodGoodGood8884589.7
March 2001GoodGoodGoodGood8884589.7
March 1999GoodGoodGoodGood8542890.0
March 1997GoodGoodGoodGood8542890.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.3,7953,66113400
Steel Protective Coatingsq. ft.33,39632,1761,22000
Deck
Reinforced Concrete Decksq. ft.26,71226,290370520
Wearing Surfacessq. ft.24,52822,332122,1840
Substructure
Reinforced Concrete Columneach1813410
Reinforced Concrete Abutmentlinear ft.35729846130
Reinforced Concrete Pier Caplinear ft.35730440130
Joints
Compression Jointlinear ft.265000265
Bearings
Elastomeric Bearingeach1212000
Movable Bearingeach6262000
Fixed Bearingeach621616246
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.5044830210
Reinforced Concrete Bridge Raillinear ft.168168000