Share:

I-40 EBL over RIO PUERCO OF THE WEST

Map

Coordinates:
+35.46114, -108.94248
35°27'40" N, 108°56'33" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I-40 EBL over RIO PUERCO OF THE WEST
Structure number:000000000006128
Location:9.2 MILES E OF ARIZ LINE
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Interstate (Rural) [01]
Length of largest span:96.1 ft. [29.3 m]
Total length:314.0 ft. [95.7 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:4.3 ft. [1.3 m]
Skew angle:30°
Owner:State Highway Agency [01]
Year built:1959
Year reconstructed:1985
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: February 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:16,410 [as of 2016]
Truck traffic:35% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:87.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
February 2017FairGoodFairSatisfactory1641087.0
February 2015FairGoodFairSatisfactory716387.0
February 2013FairGoodFairSatisfactory1501887.0
March 2011FairSatisfactoryFairFair725087.0
February 2009FairSatisfactoryFairFair1607087.0
January 2007FairSatisfactorySatisfactorySatisfactory765998.0
January 2005FairSatisfactorySatisfactorySatisfactory867897.2
January 2003FairSatisfactoryGoodSatisfactory856497.2
February 2001FairSatisfactoryGoodSatisfactory835097.2
January 1999FairSatisfactoryGoodSatisfactory690297.4
January 1997FairSatisfactoryGoodSatisfactory643597.4
January 1995FairSatisfactoryGoodSatisfactory619597.5
February 1993FairSatisfactoryGoodFair591486.5
June 1991FairGoodGoodSatisfactory632097.5

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,5751,20936150
Steel Protective Coatingsq. ft.21,39421,394000
Deck
Reinforced Concrete Decksq. ft.13,34513,345000
Wearing Surfacessq. ft.13,345013,34500
Superstructure
Steel Pin or Pin & Hangar Assemblyeach105500
Steel Protective Coatingsq. ft.518518000
Substructure
Reinforced Concrete Pier Walllinear ft.8989000
Reinforced Concrete Abutmentlinear ft.9849400
Joints
Strip Seal Jointlinear ft.154001540
Pourable Jointlinear ft.213213000
Assembly with Sealeach4343000
Bearings
Elastomeric Bearingeach1010000
Movable Bearingeach1010000
Steel Protective Coatingsq. ft.5353000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.679067900