Share:

I-10 WBL over NM-418

Map

Coordinates:
+32.24156, -107.99353
32°14'30" N, 107°59'37" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I-10 WBL over NM-418
Structure number:000000000006394
Location:14.1 Mi E Grant/Luna CL
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Rural) [01]
Length of largest span:36.1 ft. [11.0 m]
Total length:92.9 ft. [28.3 m]
Roadway width between curbs:38.4 ft. [11.7 m]
Deck width edge-to-edge:41.0 ft. [12.5 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Owner:State Highway Agency [01]
Year built:1964
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Slab [01]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: July 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:13,677 [as of 2017]
Truck traffic:34% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:84.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
July 2017FairFairFairGood1367784.0
July 2015FairFairFairGood479184.0
July 2013FairFairFairGood479184.0
July 2011FairFairFairGood818384.0
July 2009FairFairFairSatisfactory1321884.0
June 2007FairFairFairGood612084.0
March 2005FairFairFairGood611284.0
February 2003FairFairFairGood655183.3
March 2001FairFairFairGood563084.0
March 1999FairSatisfactorySatisfactoryGood515396.0
March 1997FairSatisfactorySatisfactoryGood609094.0
March 1995FairSatisfactorySatisfactoryGood576294.0
April 1993FairSatisfactorySatisfactoryGood508494.0
January 1991GoodGoodGoodGood473294.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Substructure
Reinforced Concrete Columneach40400
Reinforced Concrete Abutmentlinear ft.88780100
Reinforced Concrete Pier Caplinear ft.8484000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.21811710100
Deck
Reinforced Concrete Slabsq. ft.3,81303,81120