Share:

29-Z000 over I-10 EBLS/WBLS @MP102

Map

Coordinates:
+32.23902, -107.41838
32°14'20" N, 107°25'06" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:29-Z000 over I-10 EBLS/WBLS @MP102
Structure number:000000000006691
Location:20.5 ME JCT US-180/I-10
Purpose:Carries highway over highway
Route classification:Minor Collector (Rural) [08]
Length of largest span:58.4 ft. [17.8 m]
Total length:253.9 ft. [77.4 m]
Roadway width between curbs:30.8 ft. [9.4 m]
Deck width edge-to-edge:34.1 ft. [10.4 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Owner:State Highway Agency [01]
Year built:1967
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:5
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: March 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:770 [as of 2017]
Truck traffic:14% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:84.5

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
March 2018FairSatisfactoryGoodFair77084.5
March 2016FairSatisfactoryGoodFair40187.0
March 2014FairSatisfactoryGoodSatisfactory40198.0
March 2012FairSatisfactoryGoodSatisfactory39298.0
February 2010FairSatisfactoryGoodSatisfactory39898.0
December 2007FairSatisfactoryGoodSatisfactory40498.0
September 2005FairSatisfactoryGoodSatisfactory41498.0
October 2003FairSatisfactoryGoodSatisfactory44298.0
December 2001FairFairGoodSatisfactory45697.0
July 1999FairSatisfactoryGoodSatisfactory29596.0
September 1997FairSatisfactoryGoodSatisfactory28396.0
September 1995FairSatisfactoryGoodGood27796.0
October 1993FairSatisfactoryGoodGood27796.0
October 1991FairSatisfactoryGoodGood27196.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.1,0081,002600
Concrete Protective Coatingsq. ft.2,5772,577000
Deck
Reinforced Concrete Decksq. ft.8,6365,9392,69700
Concrete Protective Coatingsq. ft.2,0322,032000
Substructure
Reinforced Concrete Columneach86200
Concrete Protective Coatingsq. ft.1,0291,029000
Reinforced Concrete Abutmentlinear ft.6606600
Concrete Protective Coatingsq. ft.119119000
Reinforced Concrete Pier Caplinear ft.186183300
Joints
Strip Seal Jointlinear ft.186018600
Bearings
Movable Bearingeach2002000
Steel Protective Coatingsq. ft.6006000
Fixed Bearingeach2002000
Steel Protective Coatingsq. ft.5305300
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.504504000
Steel Protective Coatingsq. ft.2,2702,12015000