Share:

FR-6001 over US-60

Map

Coordinates:
+34.40534, -103.31766
34°24'19" N, 103°19'04" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FR-6001 over US-60
Structure number:000000000006948
Location:Cannon AFB Entrance
Purpose:Carries highway over highway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:138.1 ft. [42.1 m]
Total length:219.2 ft. [66.8 m]
Roadway width between curbs:44.0 ft. [13.4 m]
Deck width edge-to-edge:46.9 ft. [14.3 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:18°
Owner:State Highway Agency [01]
Year built:1970
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: October 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:7,571 [as of 2018]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Underclearances appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:82.1
Recommended work:Bridge deck rehabilitation with only incidental widening. [36]
Estimated cost of work:$380,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2018FairSatisfactorySatisfactorySatisfactory757182.1
October 2016FairSatisfactoryFairFair428471.4
October 2014FairSatisfactoryFairFair429771.4
October 2012FairSatisfactoryFairFair422682.5
November 2010FairSatisfactoryFairSatisfactory415287.6
October 2008FairSatisfactoryFairSatisfactory419987.5
November 2006FairSatisfactoryFairSatisfactory425387.5
November 2004FairSatisfactoryFairFair193686.8
October 2002PoorPoorFairFair245483.7
December 2001PoorPoorSatisfactoryFair242283.7
October 1999PoorPoorSatisfactoryFair225483.7
December 1997FairFairSatisfactoryFair217286.8
March 1996FairFairSatisfactorySatisfactory211693.8
June 1994FairSatisfactorySatisfactorySatisfactory190498.9
August 1993FairSatisfactorySatisfactorySatisfactory190498.9
August 1991FairSatisfactorySatisfactorySatisfactory10997.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,08001,08000
Steel Protective Coatingsq. ft.2,00002,00000
Deck
Reinforced Concrete Decksq. ft.10,293010,29300
Wearing Surfacessq. ft.10,29310,293000
Superstructure
Steel Pin or Pin & Hangar Assemblyeach1001000
Steel Protective Coatingsq. ft.2002000
Substructure
Reinforced Concrete Columneach60600
Concrete Protective Coatingsq. ft.100010000
Reinforced Concrete Abutmentlinear ft.9809800
Concrete Protective Coatingsq. ft.125012500
Reinforced Concrete Pier Caplinear ft.9209200
Concrete Protective Coatingsq. ft.7507500
Joints
Strip Seal Jointlinear ft.100010000
Pourable Jointlinear ft.100050500
Bearings
Movable Bearingeach1501050
Steel Protective Coatingsq. ft.1001000
Fixed Bearingeach50500
Steel Protective Coatingsq. ft.1001000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.438043800
Concrete Protective Coatingsq. ft.2,00002,00000