Share:

NM-209 over RUNNING WATER DRAW

Map

Coordinates:
+34.52911, -103.19636
34°31'45" N, 103°11'47" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:NM-209 over RUNNING WATER DRAW
Structure number:000000000007933
Location:9.0 MI N JCT US-70/CLOVIS
Purpose:Carries highway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:55.1 ft. [16.8 m]
Total length:227.0 ft. [69.2 m]
Roadway width between curbs:47.9 ft. [14.6 m]
Deck width edge-to-edge:50.9 ft. [15.5 m]
Owner:State Highway Agency [01]
Year built:1978
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Prestressed concrete continuous [6]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: March 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:4,380 [as of 2016]
Truck traffic:14% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:85.7

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
March 2017FairGoodFairFair438085.7
March 2015FairGoodFairFair410285.9
March 2013GoodGoodGoodGood411697.3
March 2011GoodGoodGoodGood436197.1
March 2009GoodGoodGoodGood416997.3
March 2007FairSatisfactorySatisfactorySatisfactory433497.2
February 2005FairGoodGoodSatisfactory413797.3
February 2003FairGoodGoodSatisfactory361897.6
February 2001FairGoodGoodSatisfactory363097.6
January 1999FairGoodGoodSatisfactory336597.8
February 1997FairGoodGoodSatisfactory261998.3
January 1996FairGoodGoodSatisfactory272098.2
February 1994FairGoodGoodSatisfactory175498.8
January 1992FairGoodGoodSatisfactory107797.3

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.1,55301,55300
Deck
Reinforced Concrete Decksq. ft.11,521011,52100
Wearing Surfacessq. ft.11,625011,62500
Substructure
Steel Columneach3003000
Steel Protective Coatingsq. ft.2,83001,9808500
Reinforced Concrete Abutmentlinear ft.112510700
Reinforced Concrete Pier Caplinear ft.165016500
Joints
Compression Jointlinear ft.126001260
Bearings
Elastomeric Bearingeach3503500
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.4924821000
Steel Protective Coatingsq. ft.1,50001,50000