Share:

US-84 over SAN JUAN DE DIOS

Map

Coordinates:
+34.77126, -104.49699
34°46'17" N, 104°29'49" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US-84 over SAN JUAN DE DIOS
Structure number:000000000008230
Location:14.2 MI S OF JCT I-40
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:60.0 ft. [18.3 m]
Total length:122.1 ft. [37.2 m]
Roadway width between curbs:44.0 ft. [13.4 m]
Deck width edge-to-edge:47.2 ft. [14.4 m]
Owner:State Highway Agency [01]
Year built:1980
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Prestressed concrete continuous [6]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Epoxy Overlay [5]

Latest Available Inspection: March 2018

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:2,316 [as of 2017]
Truck traffic:23% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:91.4

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
March 2018GoodGoodGoodGood231691.4
March 2016GoodGoodGoodGood183093.1
March 2014GoodGoodGoodGood183093.1
March 2012GoodGoodGoodGood169593.6
March 2010GoodGoodGoodGood218191.9
March 2008GoodGoodGoodGood218191.9
March 2006GoodGoodGoodGood198792.6
March 2004GoodGoodGoodGood198192.6
March 2002GoodGoodGoodGood297389.0
April 2000GoodGoodGoodGood293387.1
April 1998GoodGoodGoodGood179691.2
April 1996GoodGoodGoodGood166891.7
August 1994GoodGoodVery GoodGood133392.9
July 1992GoodGoodGoodGood138992.7
January 1991GoodGoodVery GoodGood161891.9

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.856856000
Deck
Reinforced Concrete Decksq. ft.5,7595,7015800
Wearing Surfacessq. ft.5,7595,759000
Substructure
Reinforced Concrete Columneach11000
Reinforced Concrete Abutmentlinear ft.9595000
Reinforced Concrete Pier Caplinear ft.4646000
Joints
Compression Jointlinear ft.95850100
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.276276000