Share:

43-0057 over PENISTAJA ARROYO

Map

Coordinates:
+35.94883, -107.27252
35°56'56" N, 107°16'21" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:43-0057 over PENISTAJA ARROYO
Structure number:000000000008607
Location:8.3 MI W OF NM-197
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:50.5 ft. [15.4 m]
Total length:150.9 ft. [46.0 m]
Roadway width between curbs:20.7 ft. [6.3 m]
Deck width edge-to-edge:24.3 ft. [7.4 m]
Owner:County Highway Agency [02]
Year built:1985
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Prestressed concrete [5]
Main spans design:Tee beam [04]
Deck type:Concrete Precast Panels [2]
Wearing surface:Bituminous [6]

Latest Available Inspection: September 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:103 [as of 2018]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge is scour critical; bridge foundations determined to be unstable. [3]
Sufficiency rating:70.9
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$222,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
September 2018FairSatisfactoryFairFair10370.9
September 2016FairSatisfactoryFairSatisfactory9981.9
September 2014FairSatisfactoryGoodSatisfactory9992.9
September 2012FairSatisfactoryGoodSatisfactory10092.9
September 2010FairSatisfactoryGoodSatisfactory10092.9
September 2008FairSatisfactoryGoodSatisfactory10281.9
September 2006FairSatisfactoryGoodSatisfactory10481.9
September 2004FairSatisfactoryGoodSatisfactory12981.9
November 2002FairSatisfactoryGoodSatisfactory12381.9
December 2000FairSatisfactoryGoodSatisfactory12181.9
December 1998FairSatisfactoryGoodSatisfactory11782.9
December 1996FairSatisfactoryGoodSatisfactory11182.9
December 1994FairSatisfactoryGoodFair11171.9
June 1993FairSatisfactoryGoodFair11169.9
July 1991FairSatisfactoryGoodFair10969.9

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.6045792500
Deck
Reinforced Concrete Decksq. ft.3,3153,24520500
Wearing Surfacessq. ft.3,31503,31500
Substructure
Steel Columneach1001000
Steel Protective Coatingsq. ft.200020000
Reinforced Concrete Abutmentlinear ft.85681700
Reinforced Concrete Pier Caplinear ft.855312200
Joints
Assembly without Seal Jointlinear ft.8208200
Bearings
Elastomeric Bearingeach2424000
Fixed Bearingeach2424000
Steel Protective Coatingsq. ft.4040000
Bridge Rail
Other Material Bridge Raillinear ft.30226610026