Share:

31-MC37 over FIGUREDO WASH

Map

Coordinates:
+35.77722, -108.69944
35°46'38" N, 108°41'58" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:31-MC37 over FIGUREDO WASH
Structure number:000000000008912
Location:E OF US-491 @ MP-15.2
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:20.3 ft. [6.2 m]
Total length:95.5 ft. [29.1 m]
Roadway width between curbs:12.1 ft. [3.7 m]
Deck width edge-to-edge:14.1 ft. [4.3 m]
Owner:County Highway Agency [02]
Year built:1993
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:6
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Open Grating [3]
Wearing surface:Other [9]

Latest Available Inspection: June 2017

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:336 [as of 2017]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Sufficiency rating:50.8
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$80,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2017FairSatisfactoryFairSatisfactory33650.8
June 2016FairSatisfactoryFairSatisfactory24750.8
June 2015FairSatisfactoryFairSatisfactory19450.8
June 2014FairSatisfactoryFairSatisfactory19450.8
June 2013FairSatisfactoryFairSatisfactory19250.8
June 2012FairSatisfactoryFairSatisfactory19450.8
June 2011FairSatisfactoryFairSatisfactory19450.8
June 2010FairSatisfactoryFairSatisfactory19450.8
June 2009FairSatisfactoryFairSatisfactory19850.8
June 2008FairSatisfactoryFairSatisfactory19850.8
June 2007FairSatisfactoryFairSatisfactory20250.8
June 2006FairSatisfactoryFairSatisfactory20250.8
June 2005FairSatisfactoryFairSatisfactory20650.8
June 2004GoodGoodGoodGood20260.8
July 2003GoodGoodGoodGood19860.8
July 2002GoodGoodGoodGood19060.8
August 2001GoodGoodGoodGood18659.8
August 2000GoodGoodGoodGood18659.8
August 1999GoodGoodGoodGood17859.8
August 1998GoodGoodGoodGood17859.8
August 1997GoodGoodGoodGood17059.8
August 1996GoodGoodGoodGood16658.8
August 1995GoodGoodGoodGood16657.5
August 1994GoodGoodGoodGood16657.5
August 1993GoodGoodGoodGood16657.5

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.380337700
Steel Protective Coatingsq. ft.2,0902,090000
Substructure
Steel Columneach2002000
Steel Protective Coatingsq. ft.560056000
Steel Pier Caplinear ft.141014100
Steel Protective Coatingsq. ft.400040000
Deck
Open Grid Decksq. ft.1,33501,33500
Steel Protective Coatingsq. ft.1,3351,335000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.190190000
Steel Protective Coatingsq. ft.361361000