Share:

C1-106 over Hondo River

Map

Coordinates:
+33.40916, -104.47004
33°24'33" N, 104°28'12" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:C1-106 over Hondo River
Structure number:000000000009125
Location:1.0 MI N OF JCT US-380
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:29.9 ft. [9.1 m]
Total length:105.0 ft. [32.0 m]
Roadway width between curbs:37.7 ft. [11.5 m]
Deck width edge-to-edge:41.0 ft. [12.5 m]
Owner:County Highway Agency [02]
Year built:2000
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Slab [01]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: December 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:1,110 [as of 2016]
Truck traffic:13% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Scour calculation/evaluation has not been made. [6]
Sufficiency rating:94.5

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
December 2016GoodGoodGoodGood111094.5
December 2014GoodGoodGoodGood110194.5
December 2012GoodGoodGoodGood110694.5
December 2010GoodGoodGoodGood107694.5
December 2008GoodGoodGoodGood109494.5
December 2006GoodGoodGoodGood111494.5
December 2004GoodGoodGoodGood104794.5
December 2002GoodVery GoodVery GoodVery Good97494.9
January 2001GoodVery GoodVery GoodVery Good98294.9

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Substructure
Reinforced Concrete Pier Walllinear ft.8208200
Concrete Protective Coatingsq. ft.6006000
Reinforced Concrete Abutmentlinear ft.8208200
Reinforced Concrete Pier Caplinear ft.8208200
Concrete Protective Coatingsq. ft.3003000
Joints
Pourable Jointlinear ft.164016400
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.254025400
Concrete Protective Coatingsq. ft.170017000
Deck
Reinforced Concrete Slabsq. ft.4,26404,26400
Wearing Surfacessq. ft.430043000
Concrete Protective Coatingsq. ft.334033400