Share:

FL-4710 over RIO HONDO

Map

Coordinates:
+33.39701, -104.50551
33°23'49" N, 104°30'20" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FL-4710 over RIO HONDO
Structure number:000000000009204
Location:0.2 MI N. OF JCT US-380
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:27.9 ft. [8.5 m]
Total length:33.1 ft. [10.1 m]
Roadway width between curbs:45.6 ft. [13.9 m]
Deck width edge-to-edge:54.5 ft. [16.6 m]
Skew angle:15°
Owner:City or Municipal Highway Agency [04]
Year built:1960
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 13.5 / HS 15 [3]
Main span material:Concrete [1]
Main span design:Channel beam [22]
Deck type:Concrete Precast Panels [2]
Wearing surface:Bituminous [6]

Latest Available Inspection: June 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:879 [as of 2017]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:83.5

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2017FairSatisfactoryFairSatisfactory87983.5
June 2016FairFairFairSatisfactory88582.5
June 2015FairFairFairSatisfactory722481.8
June 2014FairFairFairSatisfactory722481.8
June 2013FairFairFairSatisfactory717081.8
June 2012FairFairFairSatisfactory720281.8
June 2011FairFairFairSatisfactory725281.8
June 2010FairFairFairSatisfactory708681.8
June 2009FairFairFairSatisfactory614681.9
June 2008FairFairFairSatisfactory614681.9
June 2007FairFairFairSatisfactory616481.9
June 2006FairFairFairSatisfactory626478.9
June 2005FairSatisfactoryFairSatisfactory634379.9
March 2004FairSatisfactoryFairSatisfactory659279.8
February 2002FairSatisfactorySatisfactorySatisfactory736590.9
February 2000FairSatisfactorySatisfactorySatisfactory39591.6

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.603060300
Deck
Prestressed Concrete Top Flangesq. ft.1,94301,94300
Wearing Surfacessq. ft.1,94301,94300
Substructure
Reinforced Concrete Columneach1001000
Reinforced Concrete Pier Walllinear ft.136013600
Reinforced Concrete Abutmentlinear ft.136013600
Bearings
Other Bearingeach3800380