Share:

FDR 274 over VALLECITOS RIVER

Map

Coordinates:
+36.59229, -106.18431
36°35'32" N, 106°11'04" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FDR 274 over VALLECITOS RIVER
Structure number:030202000001023
Location:T27N;R07E;SEC09
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:25.9 ft. [7.9 m]
Total length:80.1 ft. [24.4 m]
Roadway width between curbs:14.1 ft. [4.3 m]
Deck width edge-to-edge:16.1 ft. [4.9 m]
Owner:U.S. Forest Service [64]
Year built:1959
Historic significance:Historical significance is not determinable at this time [4]
Design load:M 18 / H 20 [4]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Slab [01]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: July 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:100 [as of 1999]
Truck traffic:5% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Unknown [*]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Basically intolerable requiring high priority of corrrective action [3]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Sufficiency rating:72.1
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$500,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
July 2018FairGoodGoodSatisfactory10072.1
July 2016FairGoodGoodSatisfactory10072.1
June 2014FairSatisfactorySatisfactorySatisfactory10072.1
July 2012FairSatisfactorySatisfactorySatisfactory10077.2
June 2010FairSatisfactorySatisfactorySatisfactory10077.2
June 2008FairSatisfactorySatisfactorySatisfactory10077.2
May 2004FairSatisfactorySatisfactorySatisfactory10083.9
September 2002FairSatisfactorySatisfactorySatisfactory10077.9
June 2000FairSatisfactorySatisfactorySatisfactory10074.9