SR757 MULLER LN over E CHNL CARSON RVR
Map
Coordinates:
+38.97088, -119.8132838°58'15" N, 119°48'48" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR757 MULLER LN over E CHNL CARSON RVR |
Structure number: | B 476 |
Location: | SOUTHWEST OF GENOA |
Purpose: | Carries highway over waterway |
Route classification: | Minor Collector (Rural) [08] |
Length of largest span: | 29.9 ft. [9.1 m] |
Total length: | 75.5 ft. [23.0 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 27.9 ft. [8.5 m] |
Skew angle: | 37° |
Owner: | State Highway Agency [01] |
Year built: | 1947 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 13.5 / H 15 [2] |
Number of main spans: | 4 |
Main spans material: | Concrete continuous [2] |
Main spans design: | Slab [01] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: May 2017
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 1,500 [as of 2014] |
Truck traffic: | 5% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Countermeasures have been installed to mitigate an existing problem with scour. [7] |
Sufficiency rating: | 64.5 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $376,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2017 | Good | Good | Good | Good | 1500 | 64.5 |
May 2015 | Good | Good | Good | Good | 1500 | 64.5 |
May 2013 | Good | Good | Good | Good | 1500 | 64.5 |
May 2011 | Good | Good | Good | Good | 1500 | 63.7 |
May 2009 | Fair | Satisfactory | Satisfactory | Good | 1500 | 78.3 |
May 2007 | Fair | Satisfactory | Satisfactory | Good | 1500 | 78.3 |
September 2006 | Good | Good | Good | Good | 1500 | 78.3 |
May 2003 | Good | Good | Good | Good | 1400 | 78.4 |
May 2001 | Good | Good | Good | Good | 1400 | 79.4 |
May 1999 | Good | Good | Good | Good | 1250 | 79.6 |
May 1997 | Good | Good | Good | Good | 1070 | 79.8 |
April 1995 | Good | Good | Good | Good | 935 | 78.9 |
May 1993 | Good | Good | Good | Good | 935 | 78.9 |
May 1991 | Good | Good | Good | Good | 795 | 79.1 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Substructure |
Reinforced Concrete Column | each | 10 | 10 | 0 | 0 | 0 |
Reinforced Concrete Pier Wall | linear ft. | 35 | 0 | 35 | 0 | 0 |
Other Material Pier Wall | linear ft. | 70 | 70 | 0 | 0 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 95 | 95 | 0 | 0 | 0 |
Timber Pile | each | 32 | 32 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 70 | 70 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 131 | 0 | 31 | 100 | 0 |
Steel Protective Coating | sq. ft. | 131 | 0 | 0 | 0 | 131 |
Reinforced Concrete Bridge Rail | linear ft. | 20 | 15 | 4 | 1 | 0 |
Deck |
Reinforced Concrete Slab | sq. ft. | 2,106 | 1,776 | 330 | 0 | 0 |
Wearing Surfaces | sq. ft. | 1,804 | 1,351 | 453 | 0 | 0 |