+36.10833, -115.15833
36°06'30" N, 115°09'30" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.


Structure number:B1389
Location:LAS VEGAS
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:10.2 ft. [3.1 m]
Total length:32.5 ft. [9.9 m]
Roadway width between curbs:66.9 ft. [20.4 m]
Deck width edge-to-edge:91.9 ft. [28.0 m]
Skew angle:40°
Owner:County Highway Agency [02]
Year built:1972
Year reconstructed:1973
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: January 2017 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:28,000 [as of 2014]
Truck traffic:3% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:50.9 tons [46.3 metric tons]
Inventory rating:30.6 tons [27.8 metric tons]
Sufficiency rating:92.1

Previous Inspections 

DateSuff. RatingConditionCulvert ConditionSD/FOADT
January 201792.1Fair6 out of 10-28000
January 201592.0Fair6 out of 10-28500
January 201392.1Fair6 out of 10-28500
January 201189.7Good7 out of 10-28500
January 200993.0Good7 out of 10-28500
January 200793.0Good7 out of 10-28500
January 200593.0Good7 out of 10-28500
October 200293.0Good7 out of 10-28500
November 200093.0Fair6 out of 10-28500
November 199893.0Fair6 out of 10-28500
January 199793.5Fair6 out of 10-24800
February 199595.5Good7 out of 10-10000
December 199295.5Good7 out of 10-10000
December 199095.5Good7 out of 10-10000