Share:

I 80 over MARYS CRK

Map 

Coordinates:
+40.72167, -116.12500
40°43'18" N, 116°07'30" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:I 80 over MARYS CRK
Structure number:B1410
Location:WEST OF CARLIN
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Interstate (Rural) [01]
Length of largest span:9.8 ft. [3.0 m]
Total length:23.0 ft. [7.0 m]
Roadway width between curbs:76.1 ft. [23.2 m]
Deck width edge-to-edge:308.4 ft. [94.0 m]
Owner:State Highway Agency [01]
Year built:1976
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: July 2015 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:7,800 [as of 2014]
Truck traffic:31% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:59.8 tons [54.4 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:77.1

Previous Inspections 

DateSuff. RatingConditionCulvert ConditionSD/FOADT
July 201577.1Fair6 out of 10FO7800
July 201385.4Fair5 out of 10-7500
July 201184.7Fair5 out of 10-7000
July 200984.7Fair5 out of 10-7000
July 200784.7Fair5 out of 10-7000
August 200585.1Fair5 out of 10-5925
August 200384.8Fair5 out of 10-6820
August 200184.8Fair5 out of 10-6820
July 199985.1Fair5 out of 10-5925
September 199796.4Fair6 out of 10-5585
July 199596.5Fair6 out of 10-5070
June 199396.5Fair6 out of 10-5070
September 199197.3Fair6 out of 10-2443