Share:

SANDHILL RD over CEDAR CHNL

Map

Coordinates:
+36.16972, -115.08917
36°10'11" N, 115°05'21" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SANDHILL RD over CEDAR CHNL
Structure number:B1576
Location:LAS VEGAS
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:11.2 ft. [3.4 m]
Total length:34.1 ft. [10.4 m]
Roadway width between curbs:67.9 ft. [20.7 m]
Deck width edge-to-edge:78.1 ft. [23.8 m]
Owner:City or Municipal Highway Agency [04]
Year built:1973
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: November 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:792 [as of 2012]
Truck traffic:3% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:36.0 tons [32.7 metric tons]
Inventory rating:21.6 tons [19.6 metric tons]
Sufficiency rating:80.0

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
November 201580.0Fair6 out of 10-792
November 201380.0Good7 out of 10-792
November 201180.0Good7 out of 10-792
November 200995.9Good7 out of 10-792
November 200795.9Good7 out of 10-792
January 200695.9Good7 out of 10-720
January 200495.9Good7 out of 10-720
October 200195.9Good7 out of 10-720
January 200095.9Good7 out of 10-720
February 199895.9Good7 out of 10-720
January 199695.9Good7 out of 10-600
November 199395.9Good7 out of 10-600
February 199298.9Good8 out of 10-600