Name:BONANZA RD over SLOAN CHNL
Structure number:B1879
Location:LAS VEGAS
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Collector (Urban) [17]
Length of largest span:9.8 ft. [3.0 m]
Total length:53.2 ft. [16.2 m]
Roadway width between curbs:86.0 ft. [26.2 m]
Deck width edge-to-edge:103.4 ft. [31.5 m]
Owner:County Highway Agency [02]
Year built:1989
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:5
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: November 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:8,800 [as of 2014]
Truck traffic:3% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:59.5 tons [54.1 metric tons]
Inventory rating:35.8 tons [32.5 metric tons]
Sufficiency rating:97.2

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
November 201597.2Fair6 out of 10-8800
November 201397.0Fair6 out of 10-10500
November 201196.5Fair6 out of 10-10500
November 200996.5Good7 out of 10-10500
November 200796.5Good7 out of 10-10500
January 200697.6Fair6 out of 10-2700
January 200496.7Fair6 out of 10-9600
October 200196.7Fair6 out of 10-9600
December 199997.6Good7 out of 10-2700
March 199897.6Good7 out of 10-2700
January 199697.6Good7 out of 10-3000
November 199397.6Good7 out of 10-3000
January 199297.6Good8 out of 10-3000