Share:

RTE 5 over Genesee River

Map

Coordinates:
+42.91791, -77.75726
42°55'04" N, 77°45'26" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RTE 5 over Genesee River
Structure number:000000001001800
Location:0.5MI NW NY5+US20 +NY39
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:213.3 ft. [65.0 m]
Total length:216.9 ft. [66.1 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:43.0 ft. [13.1 m]
Owner:State Highway Agency [01]
Year built:2003
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]

Latest Available Inspection: July 2015

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:6,242 [as of 2015]
Truck traffic:16% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:96.8 tons [88.0 metric tons]
Inventory rating:57.9 tons [52.6 metric tons]
Sufficiency rating:99.0
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$2,512,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
July 201599.0GoodGoodVery GoodGood-6242
May 201399.0GoodVery GoodVery GoodVery Good-6219
May 201199.0GoodExcellentVery GoodVery Good-7372
May 200999.0GoodExcellentVery GoodVery Good-6219
May 200799.0GoodExcellentVery GoodVery Good-6101
August 200599.0GoodExcellentExcellentExcellent-7372
December 200399.0GoodExcellentExcellentExcellent-7372
November 200244.0PoorFairPoorPoorSD7372
October 200144.0PoorFairPoorPoorSD7372
October 200035.0PoorFairPoorPoorSD11840
August 199935.0PoorFairPoorPoorSD6392
August 199845.0FairFairSatisfactoryFairFO6344
May 199745.0FairFairFairFairFO6470
July 199615.2PoorPoorSeriousPoorSD6470
November 199515.2PoorPoorSeriousPoorSD6470
August 199332.2PoorPoorPoorPoorSD9683
July 199215.2PoorPoorSeriousPoorSD6470
October 199115.2PoorPoorSeriousPoorSD5567