Facts 

Name:RTE 86I over CHEMUNG RIVER
Structure number:000000001061301
Location:RTE 17 1.8 MI W CL
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Interstate (Rural) [01]
Length of largest span:113.9 ft. [34.7 m]
Total length:802.9 ft. [244.7 m]
Roadway width between curbs:39.0 ft. [11.9 m]
Deck width edge-to-edge:42.0 ft. [12.8 m]
Skew angle:30°
Owner:State Highway Agency [01]
Year built:1965
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:7
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Epoxy Overlay [5]

Latest Available Inspection: April 2015 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:10,711 [as of 2014]
Truck traffic:20% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:91.9 tons [83.5 metric tons]
Inventory rating:54.9 tons [49.9 metric tons]
Sufficiency rating:79.4
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$14,776,000

Previous Inspections 

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
April 201579.4FairSatisfactoryFairFair-10711
May 201379.4FairSatisfactoryFairFair-10711
April 201281.4FairSatisfactoryFairFair-10200
June 201179.9FairFairFairSatisfactory-18962
July 200992.5FairSatisfactorySatisfactorySatisfactory-10197
September 200780.9FairSatisfactoryFairSatisfactory-18962
July 200593.6FairSatisfactorySatisfactorySatisfactory-8594
August 200393.6FairSatisfactoryGoodSatisfactory-8594
June 200193.6FairSatisfactoryGoodSatisfactory-8594
June 199991.4FairSatisfactoryGoodSatisfactory-8594
May 199791.4FairSatisfactorySatisfactoryGood-8686
July 199580.1FairSatisfactoryFairFair-8686
June 199379.3FairFairFairFair-7291
May 199155.2FairVery GoodSatisfactoryFair-9196