Share:

RTE I278 over 3RD AVE EXIT RD

Map

Coordinates:
+40.65420, -74.00837
40°39'15" N, 74°00'30" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RTE I278 over 3RD AVE EXIT RD
Structure number:00000000106531F
Location:JCT PROSPECT EXPY & I278
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:61.0 ft. [18.6 m]
Total length:486.9 ft. [148.4 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:29.9 ft. [9.1 m]
Owner:State Highway Agency [01]
Year built:1962
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:10
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]

Latest Available Inspection: April 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:8,595 [as of 2017]
Truck traffic:13% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:77.0
Recommended work:Bridge deck replacement with only incidental widening. [37]
Estimated cost of work:$10,065,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2017FairGoodSatisfactorySatisfactory859577.0
July 2015FairGoodSatisfactorySatisfactory-79.8
July 2014FairFairFairFair777663.2
June 2013FairFairFairFair777663.2
June 2011FairFairFairFair777663.2
May 2009FairFairFairFair777663.2
May 2007FairFairFairFair777657.8
August 2005FairSatisfactoryFairFair777658.8
August 2003FairSatisfactoryFairFair777657.8
August 2001FairSatisfactoryFairFair15631527.2
July 1999FairSatisfactorySatisfactorySatisfactory15631576.0
May 1997PoorPoorPoorPoor15631519.5
April 1996PoorPoorSeriousPoor15631525.5
June 1995PoorPoorSeriousPoor15631525.5
September 1993PoorPoorPoorPoor15631548.0
August 1991PoorPoorPoorPoor15631549.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,2591,259000
Steel Protective Coatingsq. ft.9,9248,99393100
Reinforced Concrete Girder/Beamlinear ft.3512910600
Deck
Reinforced Concrete Decksq. ft.11,25511,255000
Wearing Surfacessq. ft.9,2249,224000
Superstructure
Steel Floor Beamlinear ft.379379000
Steel Protective Coatingsq. ft.1,8041,7535100
Deck
Reinforced Concrete Top Flangesq. ft.3,6303,59030100
Wearing Surfacessq. ft.2,9042,904000
Substructure
Steel Columneach115060
Steel Protective Coatingsq. ft.1,4621,35864040
Reinforced Concrete Pier Walllinear ft.266265010
Steel Pier Caplinear ft.2472020450
Steel Protective Coatingsq. ft.2,9432,688215040
Joints
Pourable Jointlinear ft.3372790580
Bearings
Movable Bearingeach1212000
Steel Protective Coatingsq. ft.4240200
Fixed Bearingeach43010
Steel Protective Coatingsq. ft.1412200
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.9649490150
Steel Protective Coatingsq. ft.9,6394,905004,734