Share:

EAST TREMONT AVE over RTE I295, RTE I295

Map

Coordinates:
+40.82217, -73.81908
40°49'20" N, 73°49'09" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:EAST TREMONT AVE over RTE I295, RTE I295
Structure number:000000001066180
Location:1 MI SE I78+I95
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:70.9 ft. [21.6 m]
Total length:147.0 ft. [44.8 m]
Roadway width between curbs:30.5 ft. [9.3 m]
Deck width edge-to-edge:278.9 ft. [85.0 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Skew angle:35°
Owner:State Highway Agency [01]
Year built:1961
Year reconstructed:2006
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Number of main spans:2
Main spans material:Prestressed concrete continuous [6]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]

Latest Available Inspection: August 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:16,142 [as of 2011]
Truck traffic:6% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Very Good [8 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:75.0
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$35,161,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2016FairSatisfactorySatisfactoryVery Good1614275.0
August 2014FairSatisfactorySatisfactoryVery Good820075.5
September 2012FairGoodSatisfactoryVery Good820075.5
November 2010FairGoodSatisfactoryVery Good820075.5
November 2008GoodExcellentExcellentVery Good820075.5
December 2006GoodExcellentExcellentGood820065.9
November 2004PoorPoorSatisfactoryFair820069.9
December 2002PoorPoorSatisfactoryFair820069.8
October 2000PoorPoorSatisfactoryFair820067.8
October 1998PoorPoorSatisfactoryFair820067.8
December 1996PoorPoorPoorPoor820058.6
November 1994PoorPoorFairPoor820059.9
November 1992PoorPoorFairPoor820059.9
July 1990PoorPoorFairPoor820059.9

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.3,0772,94296390
Deck
Reinforced Concrete Decksq. ft.31,80929,3831,5908360
Substructure
Reinforced Concrete Columneach1614020
Reinforced Concrete Abutmentlinear ft.542542000
Reinforced Concrete Pier Caplinear ft.286286000
Joints
Pourable Jointlinear ft.558274851990
Bearings
Elastomeric Bearingeach108107010
Steel Protective Coatingsq. ft.432432000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.228228000