Share:

WEEKS AVENUE over RTE I95

Map

Coordinates:
+40.84490, -73.90756
40°50'42" N, 73°54'27" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:WEEKS AVENUE over RTE I95
Structure number:000000001066300
Location:1 MI E I87+I95
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Local (Urban) [19]
Length of largest span:101.7 ft. [31.0 m]
Total length:118.1 ft. [36.0 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:62.3 ft. [19.0 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Owner:State Highway Agency [01]
Year built:1960
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Frame [07]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: April 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Truck traffic:4% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Better than present minimum criteria [7]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:89.0
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$7,920,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2016FairSatisfactorySatisfactorySatisfactory-89.0
April 2014FairSatisfactorySatisfactorySatisfactory211886.7
April 2012FairSatisfactorySatisfactorySatisfactory211886.7
June 2010FairSatisfactorySatisfactoryVery Good211886.7
May 2008FairSatisfactorySatisfactoryVery Good211886.7
May 2006FairSatisfactorySatisfactoryVery Good211886.7
May 2004FairSatisfactorySatisfactoryVery Good211886.7
August 2002FairSatisfactorySatisfactoryVery Good211886.5
June 2000FairSatisfactorySatisfactoryVery Good211886.5
May 1998FairSatisfactorySatisfactorySatisfactory211890.0
March 1996FairFairFairFair211879.7
April 1994FairFairSatisfactoryFair100074.5
May 1992FairFairSatisfactoryFair100078.6
March 1990FairFairSatisfactoryFair100078.6

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.513513000
Steel Protective Coatingsq. ft.11,27311,15300120
Deck
Reinforced Concrete Decksq. ft.6,3996,3890100
Wearing Surfacessq. ft.4,1602,9121,24800
Substructure
Reinforced Concrete Abutmentlinear ft.124124000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.205205000
Steel Protective Coatingsq. ft.1,3911,18600205