Share:

MONROE AVENUE over RTE I95, RTE 95I

Map

Coordinates:
+40.84485, -73.90666
40°50'41" N, 73°54'24" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:MONROE AVENUE over RTE I95, RTE 95I
Structure number:000000001066310
Location:1.1 MI E I87+I95
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Local (Urban) [19]
Length of largest span:101.7 ft. [31.0 m]
Total length:118.1 ft. [36.0 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:62.3 ft. [19.0 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Owner:State Highway Agency [01]
Year built:1960
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Frame [07]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: September 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Truck traffic:4% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Better than present minimum criteria [7]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:94.0
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$7,920,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
September 2016FairSatisfactoryGoodSatisfactory-94.0
November 2014FairSatisfactorySatisfactorySatisfactory94291.1
September 2012FairSatisfactorySatisfactorySatisfactory94291.1
October 2010FairSatisfactorySatisfactorySatisfactory94291.1
December 2008FairSatisfactorySatisfactorySatisfactory94291.1
November 2006FairSatisfactorySatisfactorySatisfactory94291.1
November 2004FairSatisfactorySatisfactorySatisfactory94291.1
October 2002FairSatisfactorySatisfactorySatisfactory94291.1
August 2000FairSatisfactorySatisfactorySatisfactory94291.1
May 1998FairSatisfactorySatisfactorySatisfactory94294.0
February 1996FairFairFairFair94281.9
March 1994FairFairFairFair90081.9
April 1992FairFairFairFair90078.6
March 1990FairFairSatisfactoryFair90078.6

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.515515000
Steel Protective Coatingsq. ft.8,0967,0461,05000
Deck
Reinforced Concrete Decksq. ft.6,2965,302944500
Substructure
Reinforced Concrete Abutmentlinear ft.124124000
Joints
Pourable Jointlinear ft.124124000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.202202000
Steel Protective Coatingsq. ft.1,00475425000