Share:

ROSEDALE AVENUE over RTE I95, RTE I95

Map

Coordinates:
+40.83589, -73.86999
40°50'09" N, 73°52'12" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:ROSEDALE AVENUE over RTE I95, RTE I95
Structure number:000000001066439
Location:1.6 MI NW I95+I878
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Collector (Urban) [17]
Length of largest span:53.8 ft. [16.4 m]
Total length:117.1 ft. [35.7 m]
Roadway width between curbs:74.2 ft. [22.6 m]
Deck width edge-to-edge:98.4 ft. [30.0 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:16°
Owner:State Highway Agency [01]
Year built:1954
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Frame [07]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: September 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:10,100 [as of 2011]
Truck traffic:7% of total traffic
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:77.4
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$58,108,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
September 2016Fair-FairSatisfactory1010077.4
October 2014Fair-FairSatisfactory1010077.4
September 2012Fair-FairSatisfactory1010077.4
October 2010Fair-FairSatisfactory969177.4
December 2008Fair-FairSatisfactory1189677.3
November 2006Fair-FairSatisfactory969177.4
November 2004Fair-FairSatisfactory969177.4
October 2002Fair-FairSatisfactory1253977.2
August 2000FairFairFairSatisfactory1253976.2
August 1998Fair-FairSatisfactory1253977.2
February 1996Poor-PoorFair1201359.9
February 1994Poor-PoorFair560061.1
March 1992Poor-PoorFair560061.1
March 1990Poor-PoorFair560061.1

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Substructure
Reinforced Concrete Pier Walllinear ft.9898000
Reinforced Concrete Abutmentlinear ft.196196000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.230230000
Steel Protective Coatingsq. ft.2,0701,55005200
Deck
Reinforced Concrete Slabsq. ft.10,1949,3147001800
Wearing Surfacessq. ft.8,5065,1568002,5500