Name:WHITE PLAINS ROAD over RTE I95, RTE I95
Structure number:000000001066450
Location:1.1 MI NW JCT I95 & I878
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:52.8 ft. [16.1 m]
Total length:117.1 ft. [35.7 m]
Roadway width between curbs:65.9 ft. [20.1 m]
Deck width edge-to-edge:103.4 ft. [31.5 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:29°
Owner:State Highway Agency [01]
Year built:1945
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Frame [07]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: June 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:17,375 [as of 2010]
Truck traffic:6% of total traffic
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Better than present minimum criteria [7]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:85.1
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$62,824,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2016Fair-SatisfactorySatisfactory1737585.1
June 2014Fair-SatisfactorySatisfactory2185784.8
June 2012Fair-SatisfactorySatisfactory2185784.8
July 2010Fair-SatisfactorySatisfactory2185784.8
July 2008Fair-SatisfactorySatisfactory2215284.8
April 2006Fair-SatisfactorySatisfactory2185784.8
May 2004Fair-SatisfactorySatisfactory2185784.8
May 2002Fair-SatisfactorySatisfactory2150384.8
May 2000FairSatisfactorySatisfactorySatisfactory2150384.8
May 1998FairSatisfactorySatisfactorySatisfactory2150370.6
February 1996Fair-FairFair2582375.9
February 1994Fair-FairFair1630077.4
March 1992Fair-FairFair1630077.4
March 1990Poor-PoorSatisfactory1630058.6

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Substructure
Reinforced Concrete Pier Walllinear ft.111011100
Reinforced Concrete Abutmentlinear ft.236023600
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.236023600
Steel Protective Coatingsq. ft.1,17401,17400
Deck
Reinforced Concrete Slabsq. ft.12,128012,104240
Wearing Surfacessq. ft.7,74607,74600