Share:

HUGH GRANT CIRCLE over RTE I95, RTE I95, NYCTA

Map 

Coordinates:
+40.83323, -73.86079
40°49'60" N, 73°51'39" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:HUGH GRANT CIRCLE over RTE I95, RTE I95, NYCTA
Structure number:000000001066469
Location:1 MI NW I95+I878
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:44.9 ft. [13.7 m]
Total length:95.8 ft. [29.2 m]
Roadway width between curbs:432.1 ft. [131.7 m]
Deck width edge-to-edge:633.9 ft. [193.2 m]
Vertical clearance above deck:16.1 ft. [4.9 m]
Vertical clearance below bridge:14.8 ft. [4.5 m]
Owner:State Highway Agency [01]
Year built:1955
Year reconstructed:1975
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Frame [07]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: June 2016 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:17,860 [as of 2011]
Truck traffic:6% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Better than present minimum criteria [7]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:90.6 tons [82.4 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:81.0
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$93,926,000

Previous Inspections 

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
June 201681.0FairFairFairSatisfactoryFO17860
June 201482.0Fair-FairSatisfactoryFO17342
June 201282.0Fair-FairSatisfactoryFO17900
July 201082.1Fair-FairSatisfactoryFO16034
July 200882.0Fair-FairSatisfactoryFO17055
May 200682.1Fair-FairSatisfactoryFO16034
May 200482.1Fair-FairSatisfactoryFO16034
May 200282.4Fair-FairSatisfactoryFO10200
June 200082.4FairSatisfactoryFairSatisfactoryFO10200
June 199879.4FairFairFairSatisfactoryFO10200
May 199662.2PoorFairPoorFairSD10200
April 199462.5PoorFairPoorFairSD10200
June 199262.5PoorFairPoorFairSD10200
March 199062.5PoorFairPoorFairSD10200