Share:

WILKINSON AVE over RTE I95, RTE I95

Map

Coordinates:
+40.85168, -73.82698
40°51'06" N, 73°49'37" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:WILKINSON AVE over RTE I95, RTE I95
Structure number:000000001066610
Location:1.1 MI N I295+I95
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Local (Urban) [19]
Length of largest span:67.9 ft. [20.7 m]
Total length:136.2 ft. [41.5 m]
Roadway width between curbs:49.9 ft. [15.2 m]
Deck width edge-to-edge:71.9 ft. [21.9 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Owner:State Highway Agency [01]
Year built:1961
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: April 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Truck traffic:4% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:78.0
Recommended work:Bridge deck replacement with only incidental widening. [37]
Estimated cost of work:$10,353,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2016FairFairFairSatisfactory-78.0
April 2014FairFairFairGood647562.3
March 2012FairFairFairGood647561.8
April 2010FairFairFairGood647561.8
April 2008FairFairFairGood647561.8
April 2006FairFairFairGood647561.2
March 2004FairFairFairGood647561.2
February 2002FairFairFairGood452662.6
February 2000FairFairFairGood452663.2
May 1998FairFairFairGood452663.2
March 1996PoorPoorPoorPoor452648.9
April 1994PoorPoorPoorPoor250050.2
May 1992PoorPoorPoorPoor250050.2
May 1990PoorPoorPoorPoor250050.2

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,2201201,0682210
Steel Protective Coatingsq. ft.11,64008,1483,4920
Deck
Reinforced Concrete Decksq. ft.9,7927,3612,2581730
Wearing Surfacessq. ft.6,9006,900000
Substructure
Reinforced Concrete Columneach60600
Reinforced Concrete Abutmentlinear ft.1442012220
Reinforced Concrete Pier Caplinear ft.72593100
Joints
Pourable Jointlinear ft.144142020
Bearings
Elastomeric Bearingeach2726100
Steel Protective Coatingsq. ft.135135000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.2722224820
Steel Protective Coatingsq. ft.1,38001,310700
Reinforced Concrete Bridge Raillinear ft.272026930