Share:

RTE I95 over RTE I87, RTE I87, 95I RA

Map

Coordinates:
+40.84558, -73.92671
40°50'44" N, 73°55'36" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RTE I95 over RTE I87, RTE I87, 95I RA
Structure number:000000001066850
Location:JCT I87+I95
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:112.9 ft. [34.4 m]
Total length:863.9 ft. [263.3 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:30.8 ft. [9.4 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Owner:State Highway Agency [01]
Year built:1964
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:10
Main spans material:Steel [3]
Main spans design:Girder and floorbeam system [03]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: July 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Truck traffic:10% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Better than present minimum criteria [7]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:78.0
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$18,030,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
July 2017FairFairFairFair-78.0
July 2016FairFairFairFair-78.0
July 2015FairFairFairFair-76.3
August 2013FairFairFairFair593478.0
July 2012FairFairFairFair593478.0
July 2011FairFairFairFair593478.0
August 2009FairFairFairFair593478.0
June 2007FairFairFairSatisfactory593459.0
June 2005FairFairFairSatisfactory593459.0
June 2003FairSatisfactoryFairSatisfactory593460.0
August 2001FairSatisfactoryFairSatisfactory16906660.0
July 1999FairFairFairSatisfactory16906659.0
September 1997PoorPoorFairFair16906650.6
July 1996PoorPoorPoorPoor16906645.0
June 1995PoorPoorPoorPoor16906645.0
June 1993PoorPoorPoorPoor16906645.0
August 1991PoorPoorPoorPoor16906645.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.3,4432,4231,01370
Steel Protective Coatingsq. ft.42,91227,94413,7341,2340
Steel Stringerlinear ft.2,6242,31231200
Steel Protective Coatingsq. ft.11,8367,0323,0401,7640
Deck
Reinforced Concrete Decksq. ft.29,60320,0049,502970
Wearing Surfacessq. ft.23,27622,27998890
Superstructure
Steel Floor Beamlinear ft.1,8286791,0111380
Steel Protective Coatingsq. ft.15,19910,9283,4817900
Substructure
Reinforced Concrete Columneach110533
Reinforced Concrete Abutmentlinear ft.112094180
Reinforced Concrete Pier Caplinear ft.275413410631
Joints
Strip Seal Jointlinear ft.30512518000
Assembly with Sealeach3333000
Other Jointlinear ft.3103100
Bearings
Movable Bearingeach40019210
Steel Protective Coatingsq. ft.144048960
Fixed Bearingeach4003910
Steel Protective Coatingsq. ft.100177760
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.1,624871735180
Steel Protective Coatingsq. ft.7,7972,2963,9311,5700
Reinforced Concrete Bridge Raillinear ft.100100000