Share:

RTE I278 over SLOSSON AVE

Map

Coordinates:
+40.61088, -74.11676
40°36'39" N, 74°07'00" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RTE I278 over SLOSSON AVE
Structure number:000000001067752
Location:4.5MI W JCT I278+BELT PKY
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:74.2 ft. [22.6 m]
Total length:79.1 ft. [24.1 m]
Roadway width between curbs:96.5 ft. [29.4 m]
Deck width edge-to-edge:99.4 ft. [30.3 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:11°
Owner:State Highway Agency [01]
Year built:1965
Year reconstructed:2014
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Prestressed concrete [5]
Main span design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]

Latest Available Inspection: May 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:71,305 [as of 2011]
Truck traffic:8% of total traffic
Deck condition:Excellent [9 out of 9]
Superstructure condition:Excellent [9 out of 9]
Substructure condition:Excellent [9 out of 9]
Structural appraisal:Superior to present desirable criteria [9]
Deck geometry appraisal:Better than present minimum criteria [7]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:93.6
Recommended work:Bridge deck replacement with only incidental widening. [37]
Estimated cost of work:$3,332,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2016GoodExcellentExcellentExcellent7130593.6
April 2014FairFairVery GoodGood6861670.7
April 2012FairFairVery GoodGood6861692.7
May 2010FairFairVery GoodGood6861665.4
July 2008FairFairVery GoodGood13418660.9
April 2006FairFairVery GoodGood15615759.5
April 2004FairFairVery GoodGood6861667.5
April 2002GoodGoodVery GoodGood6504868.8
March 2000GoodGoodVery GoodGood6504868.8
March 1998FairSatisfactorySatisfactoryFair7056756.5
April 1996PoorFairFairPoor5620534.0
March 1994PoorFairPoorPoor4881637.8
March 1992PoorPoorFairFair5700152.4
February 1990FairFairSatisfactoryFair5700154.7

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.1,7281,728000
Deck
Prestressed Concrete Top Flangesq. ft.7,3097,309000
Wearing Surfacessq. ft.7,0887,088000
Substructure
Reinforced Concrete Abutmentlinear ft.198198000
Bearings
Elastomeric Bearingeach4848000
Steel Protective Coatingsq. ft.9696000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.147147000