Share:

RAMP FROM WASH BR over RTE I95, RTE 95I

Map

Coordinates:
+40.84468, -73.92378
40°50'41" N, 73°55'26" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RAMP FROM WASH BR over RTE I95, RTE 95I
Structure number:000000001076360
Location:JCT I87+I95
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:164.7 ft. [50.2 m]
Total length:169.0 ft. [51.5 m]
Roadway width between curbs:25.9 ft. [7.9 m]
Deck width edge-to-edge:36.4 ft. [11.1 m]
Vertical clearance below bridge:32.8 ft. [10.0 m]
Skew angle:38°
Owner:State Highway Agency [01]
Year built:1962
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: July 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Truck traffic:4% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:88.0
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$3,268,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
July 2016FairSatisfactorySatisfactorySatisfactory-88.0
July 2014FairSatisfactorySatisfactorySatisfactory1512173.0
August 2012FairGoodGoodSatisfactory1512173.0
September 2010FairGoodGoodFair1512162.0
September 2008FairGoodGoodFair1512162.0
September 2006FairGoodGoodFair1512162.0
September 2004FairGoodGoodSatisfactory1512173.0
October 2002FairGoodGoodSatisfactory1351672.0
August 2000FairGoodGoodSatisfactory1351672.0
August 1998FairGoodGoodSatisfactory1351672.0
November 1996PoorSatisfactoryFairPoor1351648.0
November 1994PoorSatisfactoryFairPoor70055.0
October 1992PoorSatisfactoryFairPoor70055.0
December 1990PoorFairPoorFair70054.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.660660000
Steel Protective Coatingsq. ft.16,9404,23510,1642,5410
Steel Stringerlinear ft.330330000
Steel Protective Coatingsq. ft.2,2007701,100220110
Deck
Reinforced Concrete Decksq. ft.6,0065,70630000
Wearing Surfacessq. ft.4,2903,64664400
Superstructure
Steel Floor Beamlinear ft.328328000
Steel Protective Coatingsq. ft.3,7132,5991,11400
Substructure
Reinforced Concrete Abutmentlinear ft.106106000
Joints
Pourable Jointlinear ft.3680280
Assembly without Seal Jointlinear ft.3636000
Bearings
Movable Bearingeach40040
Steel Protective Coatingsq. ft.1831500
Fixed Bearingeach44000
Steel Protective Coatingsq. ft.1815300
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.330330000
Steel Protective Coatingsq. ft.1,320198660264198