Share:

RTE I895 over SLOPE ADJ TO RR

Map

Coordinates:
+40.82760, -73.88561
40°49'39" N, 73°53'08" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RTE I895 over SLOPE ADJ TO RR
Structure number:000000001076690
Location:.9 MI S JCT I95 & I895
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:75.1 ft. [22.9 m]
Total length:595.2 ft. [181.4 m]
Roadway width between curbs:21.0 ft. [6.4 m]
Deck width edge-to-edge:24.0 ft. [7.3 m]
Owner:State Highway Agency [01]
Year built:1964
Year reconstructed:1991
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:8
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]

Latest Available Inspection: May 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:7,127 [as of 2016]
Truck traffic:10% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:81.0
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$9,884,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2017FairSatisfactoryGoodFair712781.0
May 2015FairSatisfactoryGoodFair673086.0
May 2013FairSatisfactoryGoodFair3075186.0
April 2011FairSatisfactorySatisfactoryFair3075186.0
April 2009FairSatisfactorySatisfactoryFair3075186.0
April 2007FairSatisfactorySatisfactoryFair3075186.0
March 2005FairSatisfactorySatisfactoryFair3075165.7
April 2003FairSatisfactorySatisfactoryFair3075165.7
April 2001FairSatisfactorySatisfactoryFair3887865.7
April 1999FairSatisfactorySatisfactoryFair3887867.7
May 1997FairGoodFairFair3887867.7
June 1995PoorVery GoodFairPoor3887850.5
June 1993FairVery GoodSatisfactoryFair3887864.5
October 1991FairVery GoodSatisfactoryFair3887854.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.2,3642,32212300
Steel Protective Coatingsq. ft.21,84418,5241,1481,901271
Deck
Reinforced Concrete Decksq. ft.14,23213,2531788010
Wearing Surfacessq. ft.12,3504,8547,416800
Substructure
Reinforced Concrete Pier Walllinear ft.1597376100
Reinforced Concrete Abutmentlinear ft.6465530
Reinforced Concrete Pier Caplinear ft.1599256110
Joints
Assembly with Sealeach216002160
Bearings
Elastomeric Bearingeach64431920
Steel Protective Coatingsq. ft.64137260
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.1,1861,183030