Share:

RAMP TO HRD SB over RAMP TO 95I & 87I

Map

Coordinates:
+40.84548, -73.93068
40°50'44" N, 73°55'50" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RAMP TO HRD SB over RAMP TO 95I & 87I
Structure number:000000001076940
Location:JCT I87+I95
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:102.7 ft. [31.3 m]
Total length:330.7 ft. [100.8 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:31.8 ft. [9.7 m]
Vertical clearance above deck:16.1 ft. [4.9 m]
Vertical clearance below bridge:14.4 ft. [4.4 m]
Skew angle:22°
Owner:State Highway Agency [01]
Year built:1961
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Steel [3]
Main spans design:Girder and floorbeam system [03]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: October 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Truck traffic:9% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of replacement [2]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Scour condition:Bridge not over waterway. [N]
Operating rating:94.4 tons [85.8 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:77.0
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$15,736,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
October 201677.0FairSatisfactorySatisfactoryFairFO-
October 201577.0FairSatisfactorySatisfactoryFairFO-
November 201462.0FairSatisfactorySatisfactoryFairFO25515
October 201262.0FairSatisfactorySatisfactoryFairFO25515
December 201075.0FairSatisfactorySatisfactorySatisfactoryFO25515
December 200875.0FairSatisfactorySatisfactorySatisfactoryFO25515
December 200675.0FairSatisfactorySatisfactorySatisfactoryFO25515
September 200475.0FairSatisfactorySatisfactorySatisfactoryFO25515
October 200275.0FairSatisfactorySatisfactorySatisfactoryFO25515
November 200075.0FairSatisfactoryGoodSatisfactoryFO25515
December 199875.0FairSatisfactoryGoodSatisfactoryFO25515
December 199639.5PoorPoorFairPoorSD20848
August 199455.5FairFairFairFairFO20000
October 199253.5FairFairFairFairFO20000
October 199039.5PoorFairFairPoorSD20000

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.1,2481,248000
Steel Protective Coatingsq. ft.22,53611,26811,26800
Steel Stringerlinear ft.531531000
Steel Protective Coatingsq. ft.3,3223,322000
Deck
Reinforced Concrete Decksq. ft.10,9424,4746,46800
Wearing Surfacessq. ft.8,7348,734000
Superstructure
Steel Floor Beamlinear ft.744744000
Steel Protective Coatingsq. ft.6,9043,4523,45200
Substructure
Reinforced Concrete Columneach64020
Reinforced Concrete Abutmentlinear ft.86761000
Reinforced Concrete Pier Caplinear ft.109107200
Bearings
Movable Bearingeach1612220
Steel Protective Coatingsq. ft.2727000
Fixed Bearingeach1515000
Steel Protective Coatingsq. ft.2121000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.605605000
Steel Protective Coatingsq. ft.2,2222,222000