Share:

WYERS POINT ROAD over GROVES CREEK

Map

Coordinates:
+42.67989, -76.72292
42°40'48" N, 76°43'23" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:WYERS POINT ROAD over GROVES CREEK
Structure number:000000002209630
Location:5.6 MI EAST OF OVID
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:39.7 ft. [12.1 m]
Total length:45.9 ft. [14.0 m]
Roadway width between curbs:22.3 ft. [6.8 m]
Deck width edge-to-edge:24.9 ft. [7.6 m]
Skew angle:40°
Owner:Town or Township Highway Agency [03]
Year built:1936
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: September 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:55 [as of 2012]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Basically intolerable requiring high priority of replacement [2]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge is scour critical; field review indicates that extensive scour has occurred at bridge foundations. [2]
Sufficiency rating:64.2
Recommended work:Bridge deck replacement with only incidental widening. [37]
Estimated cost of work:$592,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
September 2016FairSatisfactoryFairGood5564.2
September 2014PoorPoorFairPoor5747.2
August 2012PoorPoorFairPoor9047.1
September 2010PoorPoorFairPoor8647.1
June 2009PoorPoorPoorFair9547.1
July 2008PoorPoorFairFair8661.2
July 2006PoorPoorFairFair8668.5
August 2004PoorPoorFairFair8668.5
September 2002PoorPoorFairFair8668.3
September 2000PoorPoorFairFair8668.3
August 1998PoorPoorFairFair8469.3
August 1996PoorPoorFairPoor9051.4
November 1994PoorPoorFairPoor9050.4
October 1992PoorPoorFairPoor9047.8
October 1990PoorPoorFairPoor9047.8

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.2001405514
Steel Protective Coatingsq. ft.1,548046501,083
Deck
Reinforced Concrete Decksq. ft.1,141848228650
Wearing Surfacessq. ft.736043660240
Substructure
Reinforced Concrete Abutmentlinear ft.54411210
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.9208750
Steel Protective Coatingsq. ft.31201260186