Share:

EXCHANGE STREET over SUSQUEHANNA RIVER

Map

Coordinates:
+42.09365, -75.90779
42°05'37" N, 75°54'28" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:EXCHANGE STREET over SUSQUEHANNA RIVER
Structure number:000000002226160
Location:CITY OF BINGHAMTON
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:199.8 ft. [60.9 m]
Total length:408.2 ft. [124.4 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:35.8 ft. [10.9 m]
Vertical clearance above deck:12.8 ft. [3.9 m]
Owner:City or Municipal Highway Agency [04]
Year built:1901
Year reconstructed:2015
Historic significance:Bridge is eligible for the National Register of Historic Places [2]
Design load:MS 13.5 / HS 15 [3]
Number of main spans:2
Main spans material:Steel [3]
Main spans design:Truss - Thru [10]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: October 2018

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:8,707 [as of 2013]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:43.6
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$13,956,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2018FairSatisfactoryFairSatisfactory870743.6
September 2017FairGoodFairSatisfactory872140.0
December 2016FairSatisfactoryFairSatisfactory903044.5
November 2015FairGoodSatisfactoryFair904044.5
October 2014PoorPoorPoorFair904021.6
October 2013PoorPoorPoorFair929721.3
October 2012PoorPoorPoorFair960021.0
August 2011PoorSatisfactoryPoorFair960037.7
September 2010PoorSatisfactoryPoorFair959937.7
August 2009PoorSatisfactoryPoorSatisfactory104906.0
October 2008PoorSatisfactoryPoorSatisfactory1049010.3
October 2007PoorSatisfactoryPoorSatisfactory1049010.3
November 2006PoorSatisfactoryPoorSatisfactory1236210.3
August 2005FairSatisfactoryFairSatisfactory1236232.5
November 2004FairSatisfactoryFairSatisfactory1236232.5
August 2003FairSatisfactoryFairSatisfactory1236232.5
September 2002FairSatisfactoryFairSatisfactory923733.5
August 2001FairSatisfactoryFairSatisfactory923733.5
October 2000FairSatisfactoryFairSatisfactory1086532.4
November 1999PoorGoodSeriousVery Good108656.0
October 1998PoorVery GoodSeriousVery Good108656.0
December 1997PoorGoodSeriousFair108656.0
December 1996PoorSatisfactorySeriousSerious108657.0
October 1995PoorSatisfactorySeriousSerious100007.0
October 1994PoorSatisfactorySeriousSerious100007.0
October 1993PoorVery GoodSeriousSerious100007.0
September 1992PoorVery GoodSeriousSerious100007.0
September 1991PoorVery GoodSeriousFair100007.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Stringerlinear ft.3,6003,598200
Steel Protective Coatingsq. ft.16,72816,728000
Steel Trusslinear ft.800080000
Steel Protective Coatingsq. ft.28,77428,48628800
Steel Floor Beamlinear ft.1,13809601780
Steel Protective Coatingsq. ft.9,9529,85210000
Steel Gusset Plateeach72440280
Steel Protective Coatingsq. ft.576570600
Substructure
Masonry Pier Walllinear ft.4504500
Masonry Abutmentlinear ft.9709070
Deck
Concrete Filled Grid Decksq. ft.14,24013,95602840
Wearing Surfacessq. ft.11,88011,8602000
Steel Protective Coatingsq. ft.14,24014,09814200
Joints
Pourable Jointlinear ft.108108000
Bearings
Elastomeric Bearingeach40310
Steel Protective Coatingsq. ft.80800
Movable Bearingeach1801710
Steel Protective Coatingsq. ft.1801800
Fixed Bearingeach2018200
Steel Protective Coatingsq. ft.2402400
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.8007831700
Steel Protective Coatingsq. ft.3,2003,200000