Share:

RTE 907V over ST CLAIR PLACE, 138THSTT

Map

Coordinates:
+40.82305, -73.95718
40°49'23" N, 73°57'26" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RTE 907V over ST CLAIR PLACE, 138THSTT
Structure number:000000002229339
Location:3 MI NE ROUTE 9A+79 ST
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:90.9 ft. [27.7 m]
Total length:4730.2 ft. [1441.7 m]
Roadway width between curbs:71.9 ft. [21.9 m]
Deck width edge-to-edge:78.1 ft. [23.8 m]
Vertical clearance above deck:16.1 ft. [4.9 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:
Owner:State Highway Agency [01]
Year built:1939
Year reconstructed:1982
Historic significance:Historical significance is not determinable at this time [4]
Number of main spans:64
Main spans material:Steel [3]
Main spans design:Girder and floorbeam system [03]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: April 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:132,812 [as of 2009]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:69.4
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$146,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2016FairSatisfactorySatisfactorySatisfactory13281269.4
April 2014FairSatisfactorySatisfactorySatisfactory13281265.5
April 2012FairSatisfactorySatisfactorySatisfactory13280065.5
March 2010FairSatisfactoryFairFair13281255.5
May 2008FairSatisfactoryFairFair13281255.5
June 2006FairSatisfactoryFairFair13271155.5
April 2004FairSatisfactoryFairFair13076755.5
April 2002FairSatisfactoryFairFair7518839.2
March 2000FairSatisfactoryFairFair7518839.2
May 1998FairSatisfactoryFairFair7181639.2
June 1996PoorFairPoorPoor8703450.0
June 1994PoorFairFairPoor11913544.9
July 1992PoorFairPoorPoor9943341.9
August 1990PoorPoorPoorPoor9943341.9

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.20,75116,4937933,4650
Steel Protective Coatingsq. ft.312,043301,7561,8808,137270
Steel Stringerlinear ft.21,50520,84965150
Steel Protective Coatingsq. ft.111,637109,9651,595077
Deck
Reinforced Concrete Decksq. ft.382,737381,0501,1964910
Wearing Surfacessq. ft.341,699279,07140,75821,8655
Superstructure
Steel Floor Beamlinear ft.46,55746,5270300
Steel Protective Coatingsq. ft.259,961259,79101700
Substructure
Steel Columneach1931197670
Steel Protective Coatingsq. ft.34,36030,9871,7611,56844
Reinforced Concrete Columneach11000
Reinforced Concrete Pier Walllinear ft.9369120240
Reinforced Concrete Abutmentlinear ft.150142530
Steel Pier Caplinear ft.9,8996,5061,8581,5350
Steel Protective Coatingsq. ft.87,23772,4478,6404,9761,174
Joints
Compression Jointlinear ft.5,1956674,4253766
Bearings
Movable Bearingeach22000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.14,25813,790422460