Share:

RTE 907C over FOUNTAIN AVE, SPRING CRE

Map 

Coordinates:
+40.65517, -73.85969
40°39'19" N, 73°51'35" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:RTE 907C over FOUNTAIN AVE, SPRING CRE
Structure number:000000002231539
Location:907CX SHERIDAN AVE
Purpose:Carries highway and pedestrian walkway over highway and waterway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:72.8 ft. [22.2 m]
Total length:337.0 ft. [102.7 m]
Roadway width between curbs:74.2 ft. [22.6 m]
Deck width edge-to-edge:87.6 ft. [26.7 m]
Vertical clearance below bridge:14.8 ft. [4.5 m]
Owner:State Highway Agency [01]
Year built:1941
Year reconstructed:1987
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:6
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]

Latest Available Inspection: October 2016 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:139,872 [as of 2015]
Truck traffic:5% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Operating rating:71.8 tons [65.3 metric tons]
Inventory rating:42.9 tons [39.0 metric tons]
Sufficiency rating:77.0
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$10,504,000

Previous Inspections 

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
October 201677.0FairGoodSatisfactoryGoodFO139872
December 201566.0FairSatisfactorySatisfactoryFairFO147443
May 201466.0FairGoodGoodFairFO146995
July 201366.0FairGoodGoodFairFO146995
July 201250.0PoorSatisfactoryGoodPoorSD144300
September 201150.0PoorSatisfactoryGoodPoorSD142100
June 201050.0PoorSatisfactoryGoodPoorSD144707
May 200866.0FairSatisfactoryGoodFairFO150821
April 200670.0FairSatisfactoryGoodFair-150214
June 200470.0FairSatisfactoryGoodFair-178836
June 200254.0PoorSatisfactoryGoodPoorSD130124
March 200078.1FairSatisfactorySatisfactoryGood-117821
June 199878.1FairSatisfactorySatisfactoryGood-123325
July 199646.2PoorFairFairPoorSD134223
April 199446.2PoorFairFairPoorSD125320
June 199247.2PoorSatisfactorySatisfactoryPoorSD89600
July 199061.1FairFairFairFairFO89600